Sign In | Join Free | My chinacomputerparts.com
China Lanry Instruments (Shanghai) Co., Ltd. logo
Lanry Instruments (Shanghai) Co., Ltd.
Lanry Instruments (Shanghai) Co., Ltd. Specialize In Ultrasonic Flowmeter More Than 20 Years!
Site Member

7 Years

Home > Transit Time Ultrasonic Flow Meter >

IP66 Non Fouling Heat Energy Transit Time Ultrasonic Flow Meter

Lanry Instruments (Shanghai) Co., Ltd.
Contact Now

IP66 Non Fouling Heat Energy Transit Time Ultrasonic Flow Meter

Brand Name : Lanry

Model Number : TF1100-EC

Certification : CE

Place of Origin : Shanghai, China (Mainland)

MOQ : 1 Unit

Price : Negotiable

Packaging Details : Carton package

Product Name : Ultrasonic Flow Meter Clamp On Thermal Energy Meter

Sensor type : Clamp On

Enclosure type : Wall-mounted

Degree of protection : IP66 according to EN60529

Sensor Meterial : Aluminum

Application : Nuclear Power Plant Thermal Plant Hydropower Plant Commercial Applications

Display : LCD

Supply Power : AC/DC

Contact Now

Ultrasonic Flow Meter Clamp On Thermal Energy Meter With Aluminum Sensor
The TF1100-EC ultrasonic flow meter is designed to measure the fluid velocity of liquid within a closed conduit. The transducers are a non-contacting, clamp-on type, which will provide benefits of non-fouling operation and easy installation. The TF1100-EC transit-time flow meter utilizes two transducers that function as both ultrasonic transmitters and receivers. The transducers are clamped on the outside of a closed pipe at a specific distance from each other. The transducers can be mounted in V-method where the sound transverses the pipe twice, or W-method where the sound transverses the pipe four times, or in Z-method where the transducers are mounted on opposite sides of the pipe and the sound crosses the pipe once. This selection of the mounting method depends on pipe and liquid characteristics. The flow meter operates by alternately transmitting and receiving a frequency modulated burst of sound energy between the two transducers and measuring the transit time that it takes for sound to travel between the two transducers. The difference in the transit time measured is directly and exactly related to the velocity of the liquid in the pipe. The TF1100-EC can be used for metallic, plastic and rubber tubes. Applications include Running Water, HAVC, Water Conservation, Metallurgy, Chemical Industry, Machinery, Energy.

Specifications :Transmitter

Resonse time 0.5s
Flow velocity range 0.01 to 12 m/s, bi-directional
Resolution 0.25mm/s
Repeatability 0.2% of reading
Sensitivity 0.003m/s
Accuracy ±1.0% of reading at rates >0.3 m/s);±0.003 m/s of reading at rates<0.3 m/s
Damping of displayed value 0-99s(selectable by user)
Liquid Types Supported both clean and somewhat dirty liquids with turbidity <10000 ppm
Power Supply AC: 85-265V DC: 24V/500mA
Enclosure type Wall-mounted
Degree of protection IP66 according to EN60529
Operating temperature -20℃ to +60℃
Display 4 line×16 English letters LCD graphic display, backlit
Communication 4~20mA(accuracy 0.1%),Frequency(1-9999Hz), Relay, RS232, RS485 (Modbus),Logged data
Security Keypad lockout, system lockout
Weight 2.4kg

Specifications :Transducer

Degree of protection IP65. IP67 or IP68 according to EN60529
Suited Liquid Temperature Std. Temp.: -35℃~85℃ for short periods up to 120℃
High Temp.: -35℃~200℃ for short periods up to 250℃
Pipe diameter range 20-50mm for type S, 40-1000mm for type M, 1000-6000mm for type L
Transducer Size Type S 52(h)*28(w)*26(d)mm
Type M 60(h)*34(w)*32(d)mm
Type L 80(h)*40(w)*42(d)mm
Material of transducer Aluminium for standard temp. sensor,and peek for high temp. sensor
Cable Length Std: 10m

Ultrasonic Flow Meter Clamp On Thermal Energy Meter With Aluminum Sensor ​ Features:

1.High-temperature transducer is suitable to liquids of -35℃ ~ 200℃ 
2.Do not need to shut down the pipe flow when installing the transducers
3.User-friendly configuration
4.4-20mA, Relay and OCT outputs 
5.Accuracy: 2.0% Calibrated span

Ultrasonic Flow Meter Clamp On Thermal Energy Meter With Aluminum Sensor ​ ​ Application

General
● Service and maintenance

● Energy efficiency audits

● Support of commissioning process and installation

● Replacement of defective devices

● Performance and efficiency measurement
- Evaluation and assessments
- Capacity measurement of pumps
- Monitoring of regulating valves

Packing & Delivery

Packing

With years of export experience along with excellent quality, advanced services and competitive prices, Lanry has won numerous customers' trust and support.With years of export experience along with excellent quality, advanced services and competitive prices, Lanry has won numerous customers' trust and support.

IP66 Non Fouling Heat Energy Transit Time Ultrasonic Flow MeterIP66 Non Fouling Heat Energy Transit Time Ultrasonic Flow MeterIP66 Non Fouling Heat Energy Transit Time Ultrasonic Flow Meter

Delivery

High Accuracy Low Cost Wall Mount Flow Meter standard meter: 3-7 days

Special meter: pls contact us

Express, by air, by sea can be optional.


Product Tags:

IP66 Transit Time Ultrasonic Flow Meter

      

non fouling heat energy Meter

      

IP66 heat energy Meter

      
China IP66 Non Fouling Heat Energy Transit Time Ultrasonic Flow Meter factory

IP66 Non Fouling Heat Energy Transit Time Ultrasonic Flow Meter Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Lanry Instruments (Shanghai) Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)